Welding & project operations
Welding Heat Input Calculator (kJ/mm)
This calculator works out welding arc energy and heat input in kJ/mm (and kJ/in) from the arc voltage, the welding current and the travel speed. You can enter the travel speed directly or let the tool work it out from a run length and the arc time. It applies the thermal efficiency factor k for your process from EN 1011-1 and can check the result against the maximum in your welding procedure.
- Free, no sign-up
- Runs in your browser
- Built for Islamabad & Rawalpindi
This free calculator runs in your browser and needs JavaScript. If it does not load, call or WhatsApp us on +92 304 2435577 and we will do the calculation for you.
Welding heat input is the energy delivered per millimetre of weld. Too much can soften or coarsen the heat-affected zone and reduce toughness; too little can cause lack of fusion or hard, crack-prone welds. That is why many welding procedures set limits on it, and why welders and inspectors record it run by run.
What This Tool Does
It calculates the travel speed if needed, the arc power, the gross arc energy without any efficiency factor, and the heat input with the k factor for your process. It shows the results in kJ/mm, J/mm and kJ/in, and compares them with a limit if you enter one.
Who It Is For
- Welders and supervisors recording parameters against a WPS.
- Welding inspectors checking heat input on procedure and production welds.
- Students learning how voltage, current and speed affect heat input.
How To Use It
- Choose the welding process. This sets k: 1.0 for SAW, 0.8 for SMAW, MIG/MAG and FCAW, 0.6 for TIG and plasma.
- Enter the arc voltage and welding current, read during the run.
- Enter the travel speed in mm/min, or choose “run length and arc time” and enter both.
- If your procedure states a maximum heat input, enter it.
- Click Calculate.
Inputs And Units Explained
- Arc voltage — measured as close to the arc as practical; machine display voltage includes cable losses.
- Travel speed — length of weld deposited per minute along the joint, not the wire feed speed.
- k factor — the share of arc energy that enters the work, from EN 1011-1. Some codes, including ASME IX and AWS D1.1, use arc energy without k.
How The Calculation Works
Arc energy (kJ/mm) = V × I × 60 ÷ (1000 × travel speed in mm/min). Heat input (kJ/mm) = arc energy × k. If you enter a run length and an arc time, travel speed = length (mm) ÷ (seconds ÷ 60). 1 kJ/mm = 25.4 kJ/in.
Worked Example
A stick (SMAW) run at 24 V and 180 A with a travel speed of 200 mm/min.
| Input or result | Value |
|---|---|
| Arc power | 24 × 180 = 4.32 kW |
| Arc energy | 24 × 180 × 60 ÷ (1000 × 200) = 1.296 kJ/mm |
| Heat input with k = 0.8 | 1.037 kJ/mm (26.3 kJ/in) |
Slowing the same run to 150 mm/min raises heat input by a third, to about 1.38 kJ/mm. Travel speed is often the easiest lever.
Features And Benefits
- Arc energy and heat input shown separately, so you report the right one for your code.
- Travel speed from length and time, the way it is usually measured.
- Check against a procedure limit.
- kJ/mm, J/mm and kJ/in.
Assumptions And Accuracy Limits
- For pulsed and waveform-controlled processes, voltage × current underestimates power; use instantaneous energy or power from the machine where the code requires it.
- k factors are standard values, not measurements for your set-up.
- It does not choose a heat input. Limits come from the qualified procedure and the material.
Frequently Asked Questions
What is welding heat input?
The energy delivered per unit length of weld, usually in kJ/mm. It is calculated from voltage, current and travel speed, multiplied by a process efficiency factor where the code uses one.
How do you calculate heat input in welding?
Multiply voltage by current by 60, divide by 1000 times the travel speed in mm/min, then multiply by the k factor for the process.
What is the difference between arc energy and heat input?
Arc energy is the electrical energy per millimetre. Heat input is arc energy multiplied by the thermal efficiency factor k, the share that actually enters the work.
What is the k factor for SMAW, MIG and TIG?
In EN 1011-1: 0.8 for SMAW, MIG/MAG and flux-cored, 0.6 for TIG and plasma, 1.0 for submerged arc.
Why does heat input matter?
It affects the cooling rate, and therefore the hardness, toughness and distortion of the weld and the heat-affected zone.
Related Free Tools
- Welding Joint Preparation & Bevel Geometry CalculatorDraw a V, X, bevel or square butt preparation to scale and get groove area and weld metal per metre.
- Welding Machine Duty Cycle & Cooling PlannerTurn the nameplate duty cycle into weld and rest minutes at your current, and plan a long job.
- Welding Visual Inspection Report GeneratorRecord welds, observations, defects, results and photos, then print a clean visual inspection report.
- Weld Volume, Filler & Consumables EstimatorEstimate deposited weld metal and electrode purchase from weld size, length and efficiency.
Get A Measured Quotation
For fabrication work that needs controlled, recorded welding, Ramzan Steel Works takes on steel fabrication across Islamabad and Rawalpindi.