Ramzan
Steel Works

Steel & workshop materials

Press Brake Tonnage Calculator

This calculator estimates the force needed to air-bend sheet or plate on a press brake, in tonnes and kN and per metre of bend, from the material thickness, bend length, tensile strength and V-die opening. It also gives the approximate inside radius, the minimum flange length and the suggested V-die, and checks the result against your machine’s capacity.

  • Free, no sign-up
  • Runs in your browser
  • Built for Islamabad & Rawalpindi

This free calculator runs in your browser and needs JavaScript. If it does not load, call or WhatsApp us on +92 304 2435577 and we will do the calculation for you.

Halving the V-die opening roughly doubles the force, and doubling the thickness quadruples it. Checking before bending protects the tooling and the machine.

What This Tool Does

It applies the standard air-bending formula, reports the V-to-thickness ratio and warns when the V-die is too small for the thickness.

Who It Is For

  • Press brake operators.
  • Sheet metal shops quoting bends.
  • Fabricators outsourcing bending.

How To Use It

  1. Choose the material or enter its tensile strength.
  2. Enter thickness, bend length and V-die opening.
  3. Enter machine capacity if you want a check.
  4. Click Calculate.

How The Calculation Works

F (kN) = 1.42 × UTS (MPa) × L (m) × t² (mm²) ÷ V (mm), for 90° air bending. Tonnes = kN ÷ 9.81. Inside radius ≈ 0.16 × V. Minimum flange ≈ 0.7 × V.

Worked Example

2 mm mild steel, 2.5 m long, 450 MPa, V16 die.

Input or result Value
Force about 40.7 tonnes (399 kN)
Per metre about 16.3 t/m
Inside radius about 2.6 mm

Stainless of the same thickness needs about a third more force.

Features And Benefits

  • Tonnage, radius and flange in one place.
  • Capacity check.
  • Material presets.

Assumptions And Accuracy Limits

  • Air bending only; bottoming and coining need much more force.
  • Tooling limits are often lower than the machine’s.

Common Mistakes To Avoid

  • Using too small a V-die. Force rises sharply and the bend can crack.
  • Concentrating the load. A short bend at full tonnage can damage the ram or tooling.
  • Forgetting stainless needs more force. Use its tensile strength, not mild steel’s.

Sheet Bending In Islamabad And Rawalpindi

Local sheet work for gates, shutters, ducts and enclosures is commonly 1–3 mm mild steel or galvanised sheet. Many smaller workshops send bending to shops with larger press brakes; knowing the tonnage tells you which shop can do it.

Frequently Asked Questions

How do you calculate press brake tonnage?

F (kN) = 1.42 × tensile strength (MPa) × length (m) × thickness² ÷ V-die opening.

What V-die should I use?

About 8 times the thickness for mild steel, more for thicker or stronger material.

How much tonnage to bend 3 mm mild steel?

With a 24 mm V-die, about 24 tonnes per metre.

Related Free Tools

Get A Measured Quotation

Ramzan Steel Works fabricates bent and welded sheet work in Islamabad and Rawalpindi.

Share this
0304-2435577WhatsApp Us